OWNER’S GUIDE
MODELS:
EBHN500
EBHN750
EBHN1000
EBHN1250
EBHN1500
EBHN500-8
EBHN750-8
EBHN1000-8
EBHN1250-8
EBHN1500-8
TOOLS REQUIRED
Phillips Screwdriver
Straight Screwdriver
Wire Strippers
Drill or Hammer
Level
Punch or Chisel
Drill Bits
Utility Knife
(4) Wood Screws
(3) Wire Nuts
(1) Strain Relief Connector
IMPORTANT
INSTRUCTIONS
SAVE
THESE
INSTRUCTIONS
WARNING!
Turn the electrical power off at the electrical panel
board (circuit breaker or fuse box) and lock or tag the
panel board door to prevent someone from turning
on power while you are working on the heater.
Failure to do so could result in serious electrical
shock, burns, or possible death.
When using electrical appliances, basic precautions should
always be followed to reduce the risk of fire, electric shock, and
injury to persons, including the following:
1. Read all instructions and labels before installing this heater.
2. WARNING
A heater has hot and arcing parts inside. Do not install in
areas where gasoline, paint or flammable liquids are stored or
excessive lint or dust are present.
3. WARNING
This heater is hot when in use. To avoid burns, do not let bare skin
touch hot surfaces. Keep combustible materials, such as furniture,
pillows, bedding, papers, clothes and curtains away from heater.
4. To prevent possible fire, do not block air intakes or exhaust in
any manner. Do not use on soft surfaces, like a bed, where
openings may become blocked. Heaters must be kept clean of
excessive lint, dirt and debris. (See Maintenance Instructions).
5. Risk of electrical shock. Do not insert or allow foreign objects to
enter any ventilation or exhaust opening as this may cause an
electric shock or fire, or damage the heater.
6. Do not place heater below an electrical convenience receptacle.
7. WARNING
Overheating or fire may occur. Do not install the heater behind
doors.
8. Use extreme caution when any heater is used near children or
invalids and whenever the heater is left operating unattended.
9. WARNING
Do not operate after heater malfunctions or has been dropped
or damaged in any manner.
10. WARNING
Risk of fire. Do not block heater minimum of 12 inches in front
and above, 6 inches on both sides.
11.Use this heater only as described in this manual. Any other use
not recommended by the manufacturer may cause fire, electrical
shock, or injury to persons.
12.Verify that the electrical supply wires are the same voltage as
the heater. The heater must be grounded to the grounding
screw provided. If you need to install a new circuit or need
additional wiring information, consult a qualified electrician.
Tel:
360-693-2505
www.cadetco.com
P.O.
Box
1675
Vancouver,
WA
98668-1675
Features & Benefits
Whisper quiet operation and low surface temperatures
Filled with non-toxic, non-hazardous thermal fluid
Self-contained hermetically sealed element design requires no
plumbing, piping, or other water supply
Thermal fluid capacity offers better heat retention, which creates
less cycling and keeps more consistent room temperatures
Designed to reduce the effects of indoor allergens
7-year element warranty
Page view 0
1 2 3 4 5 6 7 8 9 10

Summary of Contents

Page 1 - OWNER’S GUIDE

OWNER’S GUIDEMODELS: EBHN500 EBHN750EBHN1000 EBHN1250 EBHN1500 EBHN500-8 EBHN750-8 EBHN1000-8EBHN1250-8EBHN1500-8TOOLS REQUIRED•Phillips Screwdriver•S

Page 2 - INSTALLATION INSTRUCTIONS

CONSULTE LOS CÓDIGOS ELÉCTRICOS LOCALES PARA DETERMINAR QUÉ TRABAJOS DEBEN SER REALIZADOS POR PERSONAL DE SERVICIO ELÉCTRICO CALIFICADORuido de borbot

Page 3

THERMOSTATA thermostat is required. A Cadet wall thermostat is recommendedfor optimum performance, or you may prefer the convenience of a built-in EBK

Page 4 - STEP 4: Reassemble

INSTALLATION INSTRUCTIONSREAD ALL INSTRUCTIONS AND SAFETY INFORMATION.CAUTION - HighTemperature, KeepElectrical Cords,Drapes, And OtherFurnishings Awa

Page 5 - WARRANTIES

INSTALLATION INSTRUCTIONSInside a Softheat baseboard a hermetically sealed heat transfer fluid isheated by an electric heating element. As the soluti

Page 6 - GUÍA PARA EL PROPIETARIO

CONSULT LOCAL ELECTRICAL CODES TO DETERMINE WHAT WORK MUST BE PERFORMED BY QUALIFIED ELECTRICAL SERVICE PERSONNELGurgling noiseHeater notworkingLiquid

Page 7 - TERMOSTATO

GUÍA PARA EL PROPIETARIOMODELOS: EBHN500 EBHN750EBHN1000 EBHN1250 EBHN1500EBHN500-8 EBHN750-8 EBHN1000-8EBHN1250-8EBHN1500-8HERRAMIENTAS NECESARIAS:•D

Page 8 - Ubicación del

TERMOSTATOSe requiere un termostato. Se recomienda un termostato mural Cadetpara un óptimo rendimiento, o bien puede optar por la comodidad deun juego

Page 9 - Aire caliente

ZONA DE PERFOR. SEGURA – ARRIBAZONA DE PERFOR. SEGURA – ABAJOINSTRUCCIONES PARA LA INSTALACIÓN8. Tras confirmar que el calentador está nivelado,fije e

Page 10 - GARANTÍA

INSTRUCCIONES PARA LA INSTALACIÓNUn elemento termoeléctrico calienta el fluido térmico que se encuentra herméticamente sellado en el interior del zóca