INSTALLATION INSTRUCTIONS (continued)
__________________________
Part One
__________________________
__________________________
Part Two
__________________________
If you are installing a Multi-Watt heater, model numbers RM151, RM162, or RM168, begin with STEP 1 below. If you are installing an
RM202, RM208, RM158, or RM108, begin with STEP 2 below.
How do I install for new construction?
STEP 2
Route Supply Wires
How do I install in an existing wall?
STEP 3
Mount Wall Can
Route supply wire from circuit breaker to thermostat to wall can.
Remove a knockout and attach the supply wire with a strain relief
connector leaving 10 inches wire lead for later use. Connect sup-
ply ground wire to grounding pigtail in wall can (See Figure 5).
Proceed to PART TWO.
IMPORTANT: Insert two drywall screws into the small holes
opposite the wall stud into the drywall to rest against backside of
sheetrock (keeping wall can ush to wall).
Proceed to PART TWO.
Figure 6 Figure 7
Insert wall can, legs rst, into opening and rotate into wall. Keep-
ing front of wall can ush with nished surface, secure to wall stud
with screws through larger (3/16 inch) holes. (See Figures 6 and
7).
Element Wire Conguration (Multi-watt models RM151, RM162 and RM168 only)
STEP 1
Cadet’s Multi-Watt RM heater offers a variety of heat output options. You must rst determine the desired wattage and then congure
the heating element wire connections. The heater is shipped from the factory congured for maximum watts: 1600 Watts (240V) and
(208V) for RM162 and RM168, and 1500 Watts (120V) for RM151. If this is the wattage you desire, proceed to STEP 2.
On models RM151, RM162 and RM168, mark wiring diagram on the back of the heater with the wattage used for future reference.
Install Heater Assembly
STEP 2
Set the heater assembly (blower wheel rst) into the left side of the wall can. Fasten at top with screw provided. Unlace heater lead
wires. Connect the supply wires to the heater wires (See Figure 9). Keep all wires away from element connections when wires are
pushed into free space on right of heater.
Install Grill
STEP 3
Secure grill with the screws provided. If you have a built-in thermostat model, slide thermostat knob onto shaft. Turn power on at the
electrical panel board.
Figure 8a RM Wiring Table
Figure 9
MODEL VOLTAGE
IF YOUR DESIRED
WATTAGE IS:
YOUR WIRES WILL BE CONFIGURED LIKE THIS:
Upper Element A Lower Element C
900W-240V 700W-240V
RM162 240V
1600 Yellow Terminal X Blue Terminal Z
900 Yellow Terminal X None (*)
700 None (*) Yellow Terminal X
900W-208V 700W-208V
RM168 208V
1600 Yellow Terminal X Blue Terminal Z
900 Yellow Terminal X None (*)
700 None (*) Yellow Terminal X
1000W-120V 500W-120V
RM151 120V
1500 Yellow Terminal X Blue Terminal Z
1000 Yellow Terminal X None (*)
500 None (*) Yellow Terminal X
*Cut Blue Terminal from Red Wire and wrap up with electrical tape. Yellow
Terminal Y remains connected at B
.
Do Not Touch. Refer to Wiring Diagram on
Page 2 for terminal locations.
Figure 8b
Page 4