Cadet BTF1A Installation Guide Page 3

  • Download
  • Add to my manuals
  • Print
  • Page
    / 8
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 2
INSTALLATION INSTRUCTIONS (continued)
Wiring Instructions Conclusion - Part 3
BTF2
120 Volt
Application
RED
GROUND
SCREW
GROUND
SCREW
GROUND
SCREW
FIELD WIRING
FIELD WIRING
GROUND
SCREW
GROUND
SCREW
FIELD
WIRING
NOT
PROVIDED
FIELD WIRING
NOT PROVIDED
FIELD WIRING
NOT PROVIDED
GROUND
SCREW
FIELD WIRING
GROUND
SCREW
FIELD WIRING
NOT PROVIDED
A. Connect the red
thermostat wire labeled
L2 to the black thermostat
wire labeled OFF as
shown.
B. Connect the neutral
supply wire to one of the
heater wires.
C. Connect the supply hot wire
to the remaining red thermostat
wire.
D. Connect the remaining black
thermostat wire to the remaining
heater wire.
Proceed to Part 3.
STEP 6
Carefully tuck all wires into wiring compartment
and attach the thermostat to the baseboard
heater.
Proceed to Operating Instructions, Page 4.
MULTIPLE HEATER WIRING - OPTIONAL
More than one baseboard heater can be wired in parallel on same circuit (be sure to check national and local codes
for safety requirements). Additional wire is required. Important: When wiring multiple heaters to one thermostat, the
baseboards must be in the same room.
Maximum amperage rating: 25 amps.
BTF1
1. Disconnect one factory connector on each baseboard.
2. Connect one supply lead to the red thermostat wire.
3. Connect black thermostat wire to one wire on each heater.
4. Connect remaining wire from each heater to the remaining supply lead.
5. Connect supply ground wire to both ground screws.
IMPORTANT: Wires shown in illustration are for reference only. All electrical
work and materials must comply with the National Electric Code (NEC) and all
state and local codes.
NOTE: Field wiring is not provided.
BTF2
1. Disconnect one factory connector on each baseboard.
2. Connect one supply wire to each red thermostat wire.
3. Connect one black thermostat wire to one wire from each heater.
4. Connect remaining black thermostat wire to the remaining wire from each
heater.
5. Connect supply ground wire to both ground screws.
IMPORTANT: Wires shown in illustration are for reference only. All electrical
work and materials must comply with the National Electric Code (NEC) and all
state and local codes.
NOTE: Field wiring is not provided.
Page 3
Page view 2
1 2 3 4 5 6 7 8

Comments to this Manuals